{"id":30177,"date":"2026-06-22T16:41:44","date_gmt":"2026-06-22T14:41:44","guid":{"rendered":"https:\/\/energymonitor.tech\/?post_type=product&#038;p=30177"},"modified":"2026-09-12T10:49:23","modified_gmt":"2026-09-12T08:49:23","slug":"rozsirujici-sada-powersense-3f-600a-chytry-elektromer","status":"publish","type":"product","link":"https:\/\/energymonitor.tech\/cs\/produkt\/rozsirujici-sada-powersense-3f-600a-chytry-elektromer","title":{"rendered":"Sada pro m\u011b\u0159en\u00ed 3F spot\u0159eby do 400 kW, 600 A | EnergyMonitor"},"content":{"rendered":"<nav class=\"em-toc\">\n<ul>\n<li><a href=\"#co-je-sada-powersense\">Co je p\u0159esn\u011b roz\u0161i\u0159uj\u00edc\u00ed sada UNIT Powersense (600 A)?<\/a><\/li>\n<li><a href=\"#jak-funguje\">Jak funguje neinvazivn\u00ed m\u011b\u0159en\u00ed a p\u0159enos dat?<\/a><\/li>\n<li><a href=\"#roi-a-uspory\">N\u00e1vratnost investice (ROI): Vyplat\u00ed se v\u00e1m chytr\u00e9 m\u011b\u0159en\u00ed?<\/a><\/li>\n<li><a href=\"#pripady-pouziti\">Specifick\u00e9 p\u0159\u00edpady pou\u017eit\u00ed pro pr\u016fmysl a komerci<\/a><\/li>\n<li><a href=\"#instalace-a-kompatibilita\">Instalace, kompatibilita a integrace do syst\u00e9m\u016f<\/a><\/li>\n<li><a href=\"#bezpecnost-a-certifikace\">Ochrana dat, bezpe\u010dnost a konektivita<\/a><\/li>\n<li><a href=\"#technicke-specifikace\">Detailn\u00ed technick\u00e9 specifikace<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 id=\"co-je-sada-powersense\">Co je p\u0159esn\u011b roz\u0161i\u0159uj\u00edc\u00ed sada UNIT Powersense (600 A)?<\/h2>\n<p>Roz\u0161i\u0159uj\u00edc\u00ed sada UNIT Powersense (3 f\u00e1ze, 52 mm, 600 A) p\u0159edstavuje \u0161pi\u010dkov\u00e9 senzorick\u00e9 p\u0159\u00edslu\u0161enstv\u00ed ur\u010den\u00e9 pro monitorovac\u00ed ekosyst\u00e9m Energomonitor. V oblasti pr\u016fmyslov\u00e9ho monitoringu je \u010dastou ot\u00e1zkou, <strong>kolik stoji<\/strong> plnohodnotn\u00e1 integrace senzoriky na hlavn\u00ed p\u0159\u00edpojnice a jak se pohybuje <strong>chytr\u00fd elektrom\u011br cena<\/strong> p\u0159i aplikaci na ob\u0159\u00ed z\u00e1t\u011b\u017ee. Pr\u00e1v\u011b zde nastupuj\u00ed masivn\u00ed induk\u010dn\u00ed c\u00edvky schopn\u00e9 m\u011b\u0159it obrovsk\u00e9 objemy energie. Pokud se pt\u00e1te, <strong>jaky rozdil<\/strong> v datech z\u00edsk\u00e1te ve srovn\u00e1n\u00ed se star\u00fdmi ode\u010dty \u2013 zat\u00edmco <strong>klasicky elektromer<\/strong> generuje pouze nejasn\u00e9 kumulativn\u00ed hodnoty, <strong>chytry elektromer<\/strong> roz\u0161\u00ed\u0159en\u00fd o tyto 600A sondy poskytuje minutov\u00fd p\u0159ehled o masivn\u00edch energetick\u00fdch toc\u00edch.<\/p>\n<p>Sada obsahuje t\u0159i robustn\u00ed m\u011b\u0159ic\u00ed transform\u00e1tory (na principu CT clamp \/ CT-Klemme). Ty dok\u00e1\u017eou pojmout vodi\u010de a\u017e do p\u016fsobiv\u00e9ho pr\u016fm\u011bru 52 mm a bezpe\u010dn\u011b m\u011b\u0159it elektrick\u00e9 proudy dosahuj\u00edc\u00ed limitu 600 A na ka\u017ed\u00e9 f\u00e1zi. To odpov\u00edd\u00e1 maxim\u00e1ln\u00edmu teoretick\u00e9mu v\u00fdkonu a\u017e 400 kW, co\u017e tyto sondy nekompromisn\u011b pasuje do kategorie pro t\u011b\u017ek\u00fd pr\u016fmysl, tov\u00e1rn\u00ed instalace a centr\u00e1ln\u00ed uzly administrativn\u00edch budov.<\/p>\n<h2 id=\"jak-funguje\">Jak funguje neinvazivn\u00ed m\u011b\u0159en\u00ed a p\u0159enos dat?<\/h2>\n<p>Technologie m\u011b\u0159ic\u00edch transform\u00e1tor\u016f, tedy nasazen\u00ed CT clamp \u010didel, spo\u010d\u00edv\u00e1 ve fyzik\u00e1ln\u00edm jevu elektromagnetick\u00e9 indukce. St\u0159\u00eddav\u00fd proud prot\u00e9kaj\u00edc\u00ed tlust\u00fdm nap\u00e1jec\u00edm kabelem generuje siln\u00e9 magnetick\u00e9 pole. Samotn\u00e1 c\u00edvka, kterou obepnete kolem kabelu, zaznamen\u00e1 toto pole a p\u0159evede jej na slab\u0161\u00ed, naprosto bezpe\u010dn\u00fd m\u011b\u0159ic\u00ed proud, jen\u017e je n\u00e1sledn\u011b digitalizov\u00e1n ve vys\u00edla\u010di Powersense.<\/p>\n<ul class=\"em-feature-grid\">\n<li><strong>Extr\u00e9mn\u00ed rychlost vzorkov\u00e1n\u00ed:<\/strong> Vnit\u0159n\u00ed m\u011b\u0159en\u00ed hodnot prob\u00edh\u00e1 v neust\u00e1l\u00e9m cyklu ka\u017ed\u00fdch 6 sekund. Tato frekvence zaji\u0161\u0165uje, \u017ee nep\u0159ijdete o \u017e\u00e1dn\u00e9 kr\u00e1tkodob\u00e9 z\u00e1t\u011b\u017eov\u00e9 \u0161pi\u010dky, typick\u00e9 pro n\u00e1b\u011bh t\u011b\u017ek\u00fdch motor\u016f nebo sp\u00edn\u00e1n\u00ed kompresor\u016f.<\/li>\n<li><strong>Stabiln\u00ed bezdr\u00e1tov\u00fd p\u0159enos:<\/strong> Ve\u0161ker\u00e1 agregovan\u00e1 data z vys\u00edla\u010de Powersense jsou na zabezpe\u010den\u00e9 frekvenci odes\u00edl\u00e1na do centr\u00e1ln\u00ed jednotky (Homebase) p\u0159esn\u011b ka\u017ed\u00fdch 60 sekund. Nen\u00ed zapot\u0159eb\u00ed \u0159e\u0161it kabel\u00e1\u017e s\u00e9riov\u00fdch linek jako u standardu RS-485.<\/li>\n<li><strong>Zcela neinvazivn\u00ed metoda:<\/strong> Transform\u00e1tory pro velkou z\u00e1t\u011b\u017e maj\u00ed pevn\u00e9, rozeb\u00edrateln\u00e9 CT j\u00e1dro, nikoliv ohebnou c\u00edvku (Rogowski coil). Kle\u0161t\u011b se jednodu\u0161e zacvaknou p\u0159es izolaci vodi\u010de, \u010d\u00edm\u017e odpad\u00e1 nutnost odpojov\u00e1n\u00ed f\u00e1z\u00ed, naru\u0161en\u00ed plomb nebo v\u00fdpadk\u016f v\u00fdroby.<\/li>\n<\/ul>\n<h2 id=\"roi-a-uspory\">N\u00e1vratnost investice (ROI): Vyplat\u00ed se v\u00e1m chytre mereni?<\/h2>\n<p>Ot\u00e1zku, zda se <strong>vam chytre mereni<\/strong> vyplat\u00ed, je t\u0159eba analyzovat pohledem provozn\u00edch n\u00e1klad\u016f (OPEX), nikoliv jen po\u010d\u00e1te\u010dn\u00ed investice. V tov\u00e1rn\u00edm m\u011b\u0159\u00edtku hraje prim\u00e1rn\u00ed roli schopnost omezit pl\u00fdtv\u00e1n\u00ed a optimalizovat n\u00e1kup energie na burze nebo od dodavatele.<\/p>\n<p>Hlavn\u00edm p\u0159\u00ednosem 600A sady je dokonal\u00fd p\u0159ehled pro <strong>Peak Shaving<\/strong> (o\u0159ez\u00e1v\u00e1n\u00ed v\u00fdkonov\u00fdch \u0161pi\u010dek). Pr\u016fmyslov\u00e9 subjekty plat\u00ed horentn\u00ed sumy za rezervovanou kapacitu hlavn\u00edho jisti\u010de. P\u0159ekro\u010den\u00ed sjednan\u00e9ho \u010dtvrthodinov\u00e9ho maxima vede k drakonick\u00fdm pen\u00e1l\u00edm. Minutov\u00e1 granularita m\u011b\u0159en\u00ed (na rozd\u00edl od star\u0161\u00edch syst\u00e9m\u016f, nap\u0159\u00edklad Open Metering System (OMS) v z\u00e1kladn\u00edm profilu) umo\u017e\u0148uje p\u0159esn\u011b vid\u011bt nebezpe\u010dn\u00e9 soub\u011bhy velk\u00fdch stroj\u016f a okam\u017eit\u011b na n\u011b reagovat \u00fapravou z\u00e1t\u011b\u017ee.<\/p>\n<p>D\u00e1le se nab\u00edz\u00ed detailn\u00ed audit chodu haly b\u011bhem v\u00edkend\u016f nebo v noci. I v re\u017eimu stand-by spot\u0159ebov\u00e1vaj\u00ed ob\u0159\u00ed stroje nezanedbateln\u00e9 mno\u017estv\u00ed kWh elektrick\u00e9 energie, jeho\u017e redukce vede k okam\u017eit\u00e9 a hmatateln\u00e9 n\u00e1vratnosti n\u00e1klad\u016f.<\/p>\n<h2 id=\"pripady-pouziti\">Specifick\u00e9 p\u0159\u00edpady pou\u017eit\u00ed pro pr\u016fmysl a komerci<\/h2>\n<p>Kapacita 400 kW s pr\u016fm\u011brem izolace kabelu do 52 mm jednozna\u010dn\u011b vylu\u010duje dom\u00e1c\u00ed instalace a c\u00edl\u00ed na sofistikovanou pr\u016fmyslovou s\u00ed\u0165.<\/p>\n<ul class=\"em-feature-grid\">\n<li><strong>V\u00fdrobn\u00ed a mont\u00e1\u017en\u00ed haly:<\/strong> Komplexn\u00ed m\u011b\u0159en\u00ed celkov\u00fdch p\u0159\u00edpojnicov\u00fdch syst\u00e9m\u016f od hlavn\u00edho pr\u016fmyslov\u00e9ho transform\u00e1toru a\u017e k podru\u017en\u00fdm sekc\u00edm strojn\u00edho parku.<\/li>\n<li><strong>Datov\u00e1 a logistick\u00e1 centra:<\/strong> Neoceniteln\u00e9 p\u0159i monitorov\u00e1n\u00ed masivn\u00edch chladic\u00edch a HVAC syst\u00e9m\u016f, serverov\u00fdch farem a vzduchotechniky.<\/li>\n<li><strong>Synergie s chytrou infrastrukturou:<\/strong> I kdy\u017e sondy p\u0159\u00edmo nekomunikuj\u00ed p\u0159es Modbus TCP nebo Modbus RTU, jejich data dostupn\u00e1 p\u0159es cloud umo\u017e\u0148uj\u00ed pl\u00e1novat \u0159\u00edzen\u00ed stanic jako Wallbox pro elektromobily nebo optimalizovat provoz, k n\u011bmu\u017e jinde slou\u017e\u00ed pokro\u010dil\u00fd Datalogger \u010di dokonce bezdr\u00e1tov\u00fd PV Communicator v kombinaci se sol\u00e1rn\u00ed elektr\u00e1rnou. Takto ucelen\u00fd sb\u011br dat p\u0159ipravuje podnik pro certifikace energetick\u00e9ho managementu a standardy SG Ready.<\/li>\n<\/ul>\n<h2 id=\"instalace-a-kompatibilita\">Instalace, kompatibilita a integrace do syst\u00e9m\u016f<\/h2>\n<div class=\"em-alert-box em-alert-box--warning\"><strong>Varov\u00e1n\u00ed:<\/strong> Navzdory neinvazivn\u00edmu charakteru m\u011b\u0159en\u00ed (zacvaknut\u00ed p\u0159es st\u00e1vaj\u00edc\u00ed izolaci) sm\u00ed instalaci proudov\u00fdch sond (CT) p\u0159\u00edmo na v\u00fdkonov\u00e9 vodi\u010de v hlavn\u00edm rozv\u00e1d\u011b\u010di prov\u00e1d\u011bt pouze osoba s p\u0159\u00edslu\u0161nou odbornou elektrotechnickou kvalifikac\u00ed. Z\u00e1sadn\u011b dbejte v\u0161ech p\u0159edpis\u016f BOZP!<\/div>\n<p>Kompaktn\u00ed sondy nemohou pracovat samostatn\u011b jako izolovan\u00fd Smart Meter. Mus\u00ed b\u00fdt zapojeny sv\u00fdmi konektory do spodn\u00edch port\u016f vys\u00edla\u010de Powersense. V p\u0159\u00edpad\u011b kompletn\u00edho t\u0159\u00edf\u00e1zov\u00e9ho m\u011b\u0159en\u00ed se vyu\u017eij\u00ed v\u0161echny t\u0159i zd\u00ed\u0159ky s ozna\u010den\u00edm L1, L2 a L3. Fyzick\u00fd rozm\u011br vnit\u0159n\u00edho otvoru (a\u017e 52 mm) zaji\u0161\u0165uje, \u017ee \u010delisti pohodln\u011b obepnou i masivn\u00ed izolaci p\u0159\u00edvodn\u00edch lan.<\/p>\n<p>P\u00e1rovac\u00ed proces do domovsk\u00e9 s\u00edt\u011b prob\u00edh\u00e1 manu\u00e1ln\u00edm p\u0159epnut\u00edm centr\u00e1ln\u00ed br\u00e1ny Homebase do re\u017eimu p\u00e1rov\u00e1n\u00ed (indikovan\u00e9ho fialovou barvou obrazovky) a n\u00e1sledn\u00fdm podr\u017een\u00edm integrovan\u00e9ho tla\u010d\u00edtka na t\u011ble vys\u00edla\u010de po dobu dvou sekund.<\/p>\n<div class=\"em-alert-box em-alert-box--info\"><strong>D\u016fle\u017eit\u00e9:<\/strong> Tyto CT sondy samy o sob\u011b neslou\u017e\u00ed pro m\u011b\u0159en\u00ed, je\u017e vy\u017eaduje byrokratick\u00e9 ov\u011b\u0159en\u00ed jako certifik\u00e1ty MID\/Eichrecht pro p\u0159efakturaci t\u0159et\u00edm stran\u00e1m. Jde o mimo\u0159\u00e1dn\u011b p\u0159esn\u00e9, ale necertifikovan\u00e9 analytick\u00e9 a monitorovac\u00ed n\u00e1stroje pro intern\u00ed \u00fa\u010dely podniku.<\/div>\n<h2 id=\"bezpecnost-a-certifikace\">Ochrana dat, bezpe\u010dnost a konektivita<\/h2>\n<p>Ve sf\u00e9\u0159e pr\u016fmyslov\u00fdch instalac\u00ed nelze ignorovat kybernetickou bezpe\u010dnost. Cel\u00e1 komunika\u010dn\u00ed trasa mezi vys\u00edla\u010dem a centr\u00e1ln\u00ed jednotkou Homebase je ji\u0161t\u011bna propriet\u00e1rn\u00edm \u0161ifrovan\u00fdm r\u00e1dio sign\u00e1lem. Data jsou n\u00e1sledn\u011b odes\u00edl\u00e1na na bezpe\u010dn\u00e9 cloudov\u00e9 servery (platforma Energomonitor). Architektura s\u00edt\u011b nepou\u017e\u00edv\u00e1 ve\u0159ejn\u00e9 r\u00e1diov\u00e9 kan\u00e1ly typu LoRa nebo LoRaWAN a nepodl\u00e9h\u00e1 tak potenci\u00e1ln\u00edmu lok\u00e1ln\u00edmu zahlcen\u00ed nebo odposlechu zven\u010d\u00ed, ani nekomunikuje p\u0159es MQTT do nezn\u00e1m\u00fdch broker\u016f bez jasn\u00e9ho autoriza\u010dn\u00edho r\u00e1mce.<\/p>\n<p>Export dat pro inteligentn\u00ed budovy je zaji\u0161t\u011bn pomoc\u00ed pln\u011b zdokumentovan\u00e9ho API\/REST API. Vyu\u017eit\u00edm trval\u00fdch autentiza\u010dn\u00edch token\u016f m\u016f\u017eete kompletn\u00ed sb\u011brnu dat propojit s popul\u00e1rn\u00edmi \u0159\u00eddic\u00edmi syst\u00e9my jako Home Assistant nebo vizualiza\u010dn\u00edmi firemn\u00edmi dashboardy.<\/p>\n<h2 id=\"technicke-specifikace\">Detailn\u00ed technick\u00e9 specifikace<\/h2>\n<p>Roz\u0161\u00ed\u0159en\u00ed syst\u00e9mu Powersense p\u0159in\u00e1\u0161\u00ed p\u0159esn\u011b specifikovan\u00e9 fyzik\u00e1ln\u00ed limity, se kter\u00fdmi je nutn\u00e9 po\u010d\u00edtat v projektov\u00e9 dokumentaci instalace.<\/p>\n<table class=\"em-tech-table\">\n<tbody>\n<tr>\n<th>Typ za\u0159\u00edzen\u00ed<\/th>\n<td>Induk\u010dn\u00ed proudov\u00e9 m\u011b\u0159ic\u00ed kle\u0161t\u011b (CT clamp \/ CT-Klemme)<\/td>\n<\/tr>\n<tr>\n<th>Ur\u010den\u00ed a syst\u00e9mov\u00e1 kompatibilita<\/th>\n<td>V\u00fdhradn\u011b vys\u00edla\u010d Energomonitor Powersense a br\u00e1na Homebase<\/td>\n<\/tr>\n<tr>\n<th>Po\u010det f\u00e1z\u00ed pro m\u011b\u0159en\u00ed<\/th>\n<td>3 f\u00e1ze (T\u0159\u00edf\u00e1zov\u00e9 paraleln\u00ed m\u011b\u0159en\u00ed)<\/td>\n<\/tr>\n<tr>\n<th>Maxim\u00e1ln\u00ed dimenze m\u011b\u0159en\u00e9ho proudu<\/th>\n<td>A\u017e 600 A na ka\u017edou ze t\u0159\u00ed f\u00e1z\u00ed<\/td>\n<\/tr>\n<tr>\n<th>Maxim\u00e1ln\u00ed sou\u010dtov\u00fd v\u00fdkon syst\u00e9mu<\/th>\n<td>Do \u00factyhodn\u00fdch 400 kW<\/td>\n<\/tr>\n<tr>\n<th>Fyzick\u00fd pr\u016fm\u011br m\u011b\u0159ic\u00edho otvoru sondy<\/th>\n<td>Vodi\u010de a lana a\u017e do pr\u016fm\u011bru 52 mm<\/td>\n<\/tr>\n<tr>\n<th>Hardwarov\u00e1 vzorkovac\u00ed frekvence<\/th>\n<td>Skute\u010dn\u00e9 intern\u00ed m\u011b\u0159en\u00ed ka\u017ed\u00fdch 6 sekund<\/td>\n<\/tr>\n<tr>\n<th>Interval synchronizace do centr\u00e1ly<\/th>\n<td>Agregovan\u00e1 data p\u0159en\u00e1\u0161ena p\u0159esn\u011b ka\u017ed\u00fdch 60 sekund<\/td>\n<\/tr>\n<tr>\n<th>Metoda mont\u00e1\u017ee sond<\/th>\n<td>Bezpe\u010dn\u011b a neinvazivn\u011b zacvaknut\u00edm p\u0159es vn\u011bj\u0161\u00ed izolaci bez p\u0159eru\u0161en\u00ed okruhu<\/td>\n<\/tr>\n<tr>\n<th>RF Komunika\u010dn\u00ed protokol<\/th>\n<td>Bezpe\u010dn\u00fd propriet\u00e1rn\u00ed r\u00e1diov\u00fd p\u0159enos 433 MHz od vys\u00edla\u010de k centr\u00e1le<\/td>\n<\/tr>\n<tr>\n<th>Nadstavbov\u00e9 integrace na m\u00edru<\/th>\n<td>Rozhran\u00ed cloudu s nativn\u00ed podporou pro Home Assistant a exporty skrz API\/REST API<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<section class=\"em-product-faq\" aria-labelledby=\"em-product-faq-30177-title\">\n<div class=\"em-product-faq__eyebrow\" aria-hidden=\"true\">FAQ<\/div>\n<h2 id=\"em-product-faq-30177-title\">\u010cast\u00e9 dotazy<\/h2>\n<div class=\"em-product-faq__list\">\n<details class=\"em-product-faq__item\">\n<summary><span>Jak\u00fd maxim\u00e1ln\u00ed v\u00fdkon dok\u00e1\u017ee roz\u0161i\u0159uj\u00edc\u00ed sada UNIT Powersense 600A m\u011b\u0159it?<\/span><span class=\"em-product-faq__icon\" aria-hidden=\"true\"><\/span><\/summary>\n<div class=\"em-product-faq__answer\" id=\"em-product-faq-30177-answer-1\">\n<p>Tato t\u0159\u00edf\u00e1zov\u00e1 roz\u0161i\u0159uj\u00edc\u00ed sada je dimenzov\u00e1na pro m\u011b\u0159en\u00ed elektrick\u00fdch proud\u016f a\u017e do 600 A na jednu f\u00e1zi, co\u017e umo\u017e\u0148uje p\u0159esn\u00e9 monitorov\u00e1n\u00ed syst\u00e9m\u016f s celkov\u00fdm v\u00fdkonem dosahuj\u00edc\u00edm a\u017e 400 kW.<\/p>\n<\/div>\n<\/details>\n<details class=\"em-product-faq__item\">\n<summary><span>Je nutn\u00e9 p\u0159i instalaci sond rozpojovat f\u00e1zov\u00e9 vodi\u010de?<\/span><span class=\"em-product-faq__icon\" aria-hidden=\"true\"><\/span><\/summary>\n<div class=\"em-product-faq__answer\" id=\"em-product-faq-30177-answer-2\">\n<p>Ne, instalace je zcela neinvazivn\u00ed. M\u011b\u0159ic\u00ed transform\u00e1tory (CT clamp) s vnit\u0159n\u00edm pr\u016fm\u011brem 52 mm se pouze bezpe\u010dn\u011b zacvaknou kolem st\u00e1vaj\u00edc\u00edch izolovan\u00fdch vodi\u010d\u016f bez nutnosti p\u0159eru\u0161en\u00ed nap\u00e1jen\u00ed.<\/p>\n<\/div>\n<\/details>\n<details class=\"em-product-faq__item\">\n<summary><span>Jak \u010dasto odes\u00edl\u00e1 vys\u00edla\u010d Powersense data do centr\u00e1ln\u00ed jednotky Homebase?<\/span><span class=\"em-product-faq__icon\" aria-hidden=\"true\"><\/span><\/summary>\n<div class=\"em-product-faq__answer\" id=\"em-product-faq-30177-answer-3\">\n<p>K samotn\u00e9mu fyzick\u00e9mu m\u011b\u0159en\u00ed v induk\u010dn\u00edch c\u00edvk\u00e1ch doch\u00e1z\u00ed ka\u017ed\u00fdch 6 sekund. Vys\u00edlac\u00ed jednotka n\u00e1sledn\u011b agregovan\u00e1 data odes\u00edl\u00e1 do centr\u00e1ln\u00ed br\u00e1ny (Homebase) ka\u017ed\u00fdch 60 sekund prost\u0159ednictv\u00edm r\u00e1diov\u00e9ho sign\u00e1lu na frekvenci 433 MHz.<\/p>\n<\/div>\n<\/details>\n<details class=\"em-product-faq__item\">\n<summary><span>Lze data z m\u011b\u0159en\u00ed propojit se syst\u00e9my t\u0159et\u00edch stran jako je Home Assistant?<\/span><span class=\"em-product-faq__icon\" aria-hidden=\"true\"><\/span><\/summary>\n<div class=\"em-product-faq__answer\" id=\"em-product-faq-30177-answer-4\">\n<p>Ano, syst\u00e9m Energomonitor disponuje ofici\u00e1ln\u00edm v\u00fdvoj\u00e1\u0159sk\u00fdm rozhran\u00edm API\/REST API. Pomoc\u00ed trval\u00e9ho tokenu lze hodnoty snadno integrovat do platforem pro inteligentn\u00ed dom\u00e1cnost, jako je Home Assistant.<\/p>\n<\/div>\n<\/details>\n<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>Sada pro m\u011b\u0159en\u00ed 3F spot\u0159eby do 400 kW, 600 A slou\u017e\u00ed k m\u011b\u0159en\u00ed elekt\u0159iny a pr\u016fb\u011b\u017en\u00e9mu sledov\u00e1n\u00ed spot\u0159eby v monitorovac\u00edm syst\u00e9mu. Tato roz\u0161i\u0159uj\u00edc\u00ed sada umo\u017e\u0148uje p\u0159esn\u00e9 monitorov\u00e1n\u00ed t\u0159\u00edf\u00e1zov\u00fdch syst\u00e9m\u016f s proudem do 600 A a v\u00fdkonem a\u017e 400 kW. S pr\u016fm\u011brem 52 mm je ide\u00e1ln\u00ed pro pr\u016fmysl a komer\u010dn\u00ed objekty.<\/p>\n","protected":false},"featured_media":32561,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[240],"product_tag":[],"class_list":["post-30177","product","type-product","status-publish","has-post-thumbnail","product_cat-energymonitor-cs","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/product\/30177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/comments?post=30177"}],"version-history":[{"count":4,"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/product\/30177\/revisions"}],"predecessor-version":[{"id":31774,"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/product\/30177\/revisions\/31774"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/media\/32561"}],"wp:attachment":[{"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/media?parent=30177"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/product_brand?post=30177"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/product_cat?post=30177"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/energymonitor.tech\/cs\/wp-json\/wp\/v2\/product_tag?post=30177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}